your Honda EU20i inverter generator will be running smooth and efficently with this genuine Honda service kit
Kit includes:
The purpose of the maintenance schedule is to keep the generator in the best operating condition.
Inspect or service as scheduled in the table below.
WARNING:
Shut off the engine before performing and maintenance. If the engine must be run, make sure the area is well ventilated. The exhaust contains poisonous carbon monoxide gas.
CAUTION:
Use genuine Honda parts or equivalent. The use of replacement parts which are not equivalent quality may damage the generator.
REGULAR SERVICE PERIODS (3) |
Each use |
First month or 20 hrs. |
Every 3 months or 50 hrs. |
Every 6 months or 100 hrs. |
Every year or 200 hrs. |
||
ITEM |
|||||||
Performed at every indicated month or operating hour interval, whichever comes first. |
|||||||
Engine oil |
Check level |
○ |
|
|
|
|
|
Change |
|
○ |
|
○ |
|
||
Air cleaner |
Check |
○ |
|
|
|
|
|
Clean |
|
|
○ (1) |
|
|
||
Spark plug |
Check-adjust |
|
|
|
○ |
|
|
Replace |
|
|
|
|
○ |
||
Spark arrester |
Clean |
|
|
|
○ |
|
|
Valve Clearance |
Check-adjust |
|
|
|
|
○ (2) |
|
Combustion chamber |
Clean |
After every 300 hrs (2) |
|||||
Fuel tank & filter |
Clean |
|
○ (2) |
|
|||
Fuel line |
Check |
Every 2 years (Replace if necessary) (2) |
NOTE:
(1)Service more frequently when used in dusty areas.
(2)These items should be serviced by your servicing dealer, unless you have proper tools and are mechanically proficient. Refer to Honda shop manual for service procedures.
(3)For commercial use, log hours of operation to determine proper maintenance intervals.